Sensing method: Narrow-beam reflective.
Connection method: Pre-wired.
Sensing distance: 90±30 mm.
Model: PNP output.
Small 2.5-mm-diameter Spot Ideal for.
Detecting Small Workpieces.
Tiny workpieces as little as 0.1 mm in diameter can be,
detected with the 2.5-mm-dia. spot.
The narrow beam enables sensing from small slots or holes E2K-X4MY1 INSTRUCTION sheet.
The small spot of light enables visual checking of sensing,
spot position
E2K-X4MY1
IP67 degree of protection, mutual interference prevention,
and EN standard compliance. Size: 48 x 96mm.
Control output 1: relay output.
Control output 2: relay output.
Auxiliary output: 2 independent points.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type E2K-X4MY1 INSTRUCTION sheet.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: -.
Event input: 6 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm E2K-X4MY1 INSTRUCTION sheet.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Terminal type: Exposed-lead Models.
Protective tubing diameter D: 6.4 dia.
Protective tubing length L: 50cm.
Lead wire type: Standard.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperaature Sensors E2K-X4MY1 Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2K-X4MY1 Manual.