OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E2EM-X4X2-M1J Manual E2EM-X4X2-M1J INSTRUCTION sheet

OMRON E2EM-X4X2-M1J Manual E2EM-X4X2-M1J INSTRUCTION sheet

Brand: OMRON
Product model: E2EM-X4X2-M1J
Name: proximity switch
Sort: INSTRUCTION sheet
File language: English
File size: 1.34MB
Lead wire length: 1m.
Element type: J (IC).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2EM-X4X2-M1J INSTRUCTION sheet E2EM-X4X2-M1J Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: -- E2EM-X4X2-M1J INSTRUCTION sheet.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0 E2EM-X4X2-M1J INSTRUCTION sheet. 5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / mannual, RUN/STOP, alarm), interactive display PV/SV E2EM-X4X2-M1J Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E2EM-X4X2-M1J Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Long-distance Proximity Sensor
E2EM-X2C1-M1
OMRON Long-distance Proximity Sensor E2EM-X2C1-M1
Appearance: Shielded, M8. Sensing distance:
OMRON
Long-distance Proximity Sensor
E2EM-X4C2 2M
OMRON Long-distance Proximity Sensor E2EM-X4C2 2M
Appearance: Shielded, M12. Sensing distance:
OMRON
Long-distance Proximity Sensor
E2EM-X8X2 2M
OMRON Long-distance Proximity Sensor E2EM-X8X2 2M
Appearance: Shielded, M18. Sensing distance:
OMRON
Long-distance Proximity Sensor
E2EM-X8X1 2M
OMRON Long-distance Proximity Sensor E2EM-X8X1 2M
Appearance: Shielded, M18. Sensing distance: