OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E2EH-X12B2-M1 Manual E2EH-X12B2-M1 INSTRUCTION sheet

OMRON E2EH-X12B2-M1 Manual E2EH-X12B2-M1 INSTRUCTION sheet

Brand: OMRON
Product model: E2EH-X12B2-M1
Name: proximity switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.59MB
Size: M12 (Brass); Single; Unshielded.
Sensing distance: 10 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Control output: Voltage output.
Auxiliary output: Two.
Communications: RS-485 E2EH-X12B2-M1 INSTRUCTION sheet.
Heater burnot: Detection for Single-phase heater.
Event inputs: -- E2EH-X12B2-M1
Power supply voltage: 24 VAC/VDC.
The E5DC-800 Mounts to DIN Track and Is Ideal,
for Connections to HMIs and PLCs.
It provides the Same Easy Operation and,
Advanced Performance as the Rest of the,
E5@C-800 Series.
A slim body at 85 × 22.5 mm (D × W) that fits into narrow control,
panels and mounts to DIN Track.
Removable terminal block for easy replacement to simplify maintenance E2EH-X12B2-M1 INSTRUCTION sheet.
High-speed sampling at 50 ms for applications with high-speed,
temperature increases.
Easy connections to a PLC with programless communications.
Models are available with up to 2 auxiliary outputs and 1 event input to,
complete basic functions.
A white PV display (height: 8.5 mm) is easy to read when setting up,
checking alarms, and making settings in a control panel E2EH-X12B2-M1 INSTRUCTION sheet. Protective tubing length: 100mm.
Lead wire length: 1m.
Element type: J (IC).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / mannual, RUN/STOP, alarm), interactive display PV/SV E2EH-X12B2-M1 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E2EH-X12B2-M1 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Proximity Sensor
E2EH-X7C2 2M
OMRON Proximity Sensor E2EH-X7C2 2M
Appearance: Shielded, M18. Sensing distance:
OMRON
Proximity Sensor
E2EH-X3D1 2M
OMRON Proximity Sensor E2EH-X3D1 2M
Appearance: Shielded, M12. Sensing distance:
OMRON
Proximity Sensor
E2EH-X12D1-T 2M
OMRON Proximity Sensor E2EH-X12D1-T 2M
Appearance: Shielded, M30. Sensing distance:
OMRON
Proximity Sensor
E2EH-X7B1-M1
OMRON Proximity Sensor E2EH-X7B1-M1
Appearance: Shielded, M18. Sensing distance: