Appearance: Shielded, M18.
Sensing distance: 7 mm.
Output configuration: DC 2-wire (polarity).
Operation mode: NC.
Proximity Sensor Ideal for the Food and Beverage Industry. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 8 dia.
Protective tubing length L: 50 cm E2E-S05S12-CJ-C2 INSTRUCTION sheet.
A Wide Variety of High-precision.
Temperature Sensors
E2E-S05S12-CJ-C2
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2E-S05S12-CJ-C2 INSTRUCTION sheet. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E2E-S05S12-CJ-C2 INSTRUCTION sheet.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Sensing method: BGS reflective (fixed distance).
Connection method: Pre-wired (2 m).
Sensing distance: 10 to 200 mm.
Model: PNP output .
Stainless Steel Housing Ideal for Food Industry PAT Pending.
Strong resistance against detergents, disinfectants, and jet liquid flow.
Product lineup includes BGS Reflective Models and Through-beam,
Models with built-in slits.
Certified by Ecolab Europe. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-QTC;
Resistance thermometer input, E5GN-QP.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Tempperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E2E-S05S12-CJ-C2 Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E2E-S05S12-CJ-C2 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.