OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON E2C-GE4B Manual E2C-GE4B INSTRUCTION sheet

OMRON E2C-GE4B Manual E2C-GE4B INSTRUCTION sheet

Brand: OMRON
Product model: E2C-GE4B
Name: proximity sensor
Sort: INSTRUCTION sheet
File language: English
File size: 1.14MB
Size: 1/4 DIN 96 × 96 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC.
Input type: Analog (current/voltage).
Alarm output: 3.
Control output: Voltage output(for driving SSR).
Functions: Heater burnout, Yes (CT1); Mounting option units, Yes.
Previous model: None.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better E2C-GE4B INSTRUCTION sheet.
Controllers now available with analog inputs E2C-GE4B
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications E2C-GE4B INSTRUCTION sheet.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Size: M8, Shielded.
Sensing distance: 2.0 mm.
Connection: M8 connector (3-pin).
Body material: Stainless steel.
Thread length (overall length): 27 (39).
Output configuration: NPN.
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1 E2C-GE4B INSTRUCTION sheet. 5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Control output: relay output.
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: screw terminal table type (main unit + terminal unit).
Power supply voltage: AC100 ~ 240V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type.
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating.
Easy to connect with PLC through no program communication.
The use of communicatioon adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately) E2C-GE4B Manual.
With auxiliary output (maximum 2 points), event input (maximum 1 points), tthe basic function is complete E2C-GE4B Manual.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8.5mm).