OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON DRT2-ID04CL-1 Manual DRT2-ID04CL-1 INSTRUCTION Manual

OMRON DRT2-ID04CL-1 Manual DRT2-ID04CL-1 INSTRUCTION Manual

Brand: OMRON
Product model: DRT2-ID04CL-1
Name: remote i/o terminal
Sort: INSTRUCTION Manual
File language: English
File size: 0.36MB
Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms DRT2-ID04CL-1 INSTRUCTION Manual.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement DRT2-ID04CL-1
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Type of drive rod: plunger type DRT2-ID04CL-1 INSTRUCTION Manual.
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm DRT2-ID04CL-1 INSTRUCTION Manual.
Elevator and escalator can be used. Type: Welding / wire type, with left column.
Drive rod: R blade Shibai rod type.
Terminal specifications: with wire, the left side.
Contact specifications: 1a.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Head material: Plastic.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC/1NO+2NC.
Conduit opening: M20.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectaable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility DRT2-ID04CL-1 Manual.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for eithher standard loads or microloads DRT2-ID04CL-1 Manual.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available.
Related products
OMRON
Waterproof Terminals
SRT2-OD04CL-1
OMRON Waterproof Terminals SRT2-OD04CL-1
Input/Output: Outputs. Internal I/O circuit
OMRON
Screw-less Clamp Terminals with Transistors
DRT2-ID16SLH
OMRON Screw-less Clamp Terminals with Transistors DRT2-ID16SLH
Short/disconnection detection: Supported. Sp