OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON D4SL-N2DFG Manual D4SL-N2DFG INSTRUCTION sheet

OMRON D4SL-N2DFG Manual D4SL-N2DFG INSTRUCTION sheet

Brand: OMRON
Product model: D4SL-N2DFG
Name: guard lock safety-door switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.63MB
The type of the drive lever: one way action roller rocker type (horizontal action).
Conduit size: single catheter type, M20.
Built in switch structure: slow motion (1NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC) D4SL-N2DFG INSTRUCTION sheet D4SL-N2DFG
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.
Elevator and escalator can be used. Release key type: Trapped key *1.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO D4SL-N2DFG INSTRUCTION sheet.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas D4SL-N2DFG INSTRUCTION sheet.
IP67 degree of protection. Actuator: Plunger.
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Fork lever lock (left operation).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact formms D4SL-N2DFG Manual.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used witth both standard loads and microloads D4SL-N2DFG Manual.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC.