OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON D4NS-6AF Manual D4NS-6AF INSTRUCTION sheet

OMRON D4NS-6AF Manual D4NS-6AF INSTRUCTION sheet

Brand: OMRON
Product model: D4NS-6AF
Name: safety-door switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.56MB
Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: SJT(O) cable *3.
Actuator: Sealed roller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4NS-6AF INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4NS-6AF
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4NS-6AF INSTRUCTION sheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release D4NS-6AF INSTRUCTION sheet.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key inssertion point D4NS-6AF Manual.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4NS-6AF Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.
Related products
OMRON
Safety-door Switch
D4NS-2EF
OMRON Safety-door Switch D4NS-2EF
Type: 1-Conduit. Contact configuration: Slow
OMRON
Safety-door Switch
D4NS-1AF
OMRON Safety-door Switch D4NS-1AF
Type: 1-Conduit. Contact configuration: Slow
OMRON
Safety-door Switch
D4NS-8FF
OMRON Safety-door Switch D4NS-8FF
Type: 2-Conduit. Contact configuration: Slow
OMRON
Safety-door Switch
D4NS-9BF
OMRON Safety-door Switch D4NS-9BF
Type: 1-Conduit, with connector. Contact con