OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON D4N-8287 Manual D4N-8287 INSTRUCTION sheet

OMRON D4N-8287 Manual D4N-8287 INSTRUCTION sheet

Brand: OMRON
Product model: D4N-8287
Name: safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @ D4N-8287 INSTRUCTION sheet.
Conduit size (See Note D4N-8287): 1/2-14NPT.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available) D4N-8287 INSTRUCTION sheet.
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4N-8287 INSTRUCTION sheet.
The plastic material makes the Slide Key suitable,
for lightweight doors. Specifications: I/O; NPN (input: + common,
output: - common); 8 inputs/8 outputs.
I/O connections: Sensor connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage:
Supplied from external source for outputs.
Includes Sensor Connector That Conforms to,
Industry Standards And Can Be Used to Connect.
Sensors with Pre-wired Cables without Using,
Special Tools.
Equipped with the standard Smart Slave,
functions that provide powerful.
preventative maintenance and,
troubleshooting capabilities.
Digital I/O Terminal compatible with,
industry-standard sensor connectors.
Connect sensors easily without special tools.
Reduce time required for wiring.
Load short-circuit detection. Head material: Plastic*1.
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC/1NO+2NC.
Conduit opening: Pg13.5.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Seelectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility D4N-8287 Manual.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for eithher standard loads or microloads D4N-8287 Manual.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available.
Related products
OMRON
Safety Limit Switch
D4N-2172
OMRON Safety Limit Switch D4N-2172
Actuator: One-way roller arm lever vertical
OMRON
Safety Limit Switch
D4N-2D2G
OMRON Safety Limit Switch D4N-2D2G
Actuator: Adjustale roller lever, form lock
OMRON
Pull-reset Safety Limit Switch
D4N-2D2HR
OMRON Pull-reset Safety Limit Switch D4N-2D2HR
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-2B25
OMRON Safety Limit Switch D4N-2B25
Actuator: Roller lever resin lever, metal ro