Ratings: 0.1 A.
Actuator: Short hinge lever.
Terminals: Molded lead wires (300 mm).
Contact form: SPDT.
Sealed Miniature Basic.
Switch Conforms to IP67.
(Excluding the terminals on terminal models).
Use of epoxy resin assures stable sealing, making.
this switch ideal for places subject to water spray D4N-4BLE INSTRUCTION sheet.
or excessive dust.
V-series internal mechanism assures high
D4N-4BLE
precision and durability. The mounting is the,
same as of the V models.
Ideal for automobiles, agricultural machines,
large-scale home appliances, and industrial,
equipment, which require high environmental resistance. Actuator: Short hinge lever.
Economical, High Utility Enclosed Switch.
Enclosed Switches with Built-in Basic Switches for High,
Repeatability and Durability of 10 Million Operations Minimum D4N-4BLE INSTRUCTION sheet.
Panel mount versions have the same operating position as,
Z Basic Switch.
Suitable for applications demanding higher mechanical,
strength, dustproof and drip-proof properties than those,
on basic switches.
Resin molded terminal versions are available.
Approved by UL, CSA, and CCC (Chinese standard) D4N-4BLE INSTRUCTION sheet.
(Ask your OMRON representative for information on approved models.). Actuator: Roller lever (metal lever, resin roller).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Distributed Safety Terminals That.
Reduce Wiring.
Lineup inncludes four models to accommodate various,
I/O types and number of I/O points D4N-4BLE Manual.
Monitor the safety system from Standard Controllers,
across the network.
EN954-1 (Cat.4), ISO13849-1 (PLe),
and IEC 61508 SIL3 certification.
The DST1-XD0808SL-1 also supports logic operation,
functions for high-speed processing in applications,
requiring partial stopping of the safety system D4N-4BLE Manual.