OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON D4N-2F2H Manual D4N-2F2H INSTRUCTION sheet

OMRON D4N-2F2H Manual D4N-2F2H INSTRUCTION sheet

Brand: OMRON
Product model: D4N-2F2H
Name: safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller lever.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4N-2F2H INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4N-2F2H
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables D4N-2F2H INSTRUCTION sheet.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Lock method: Mechanical lock.
Conduit size: M20.
Voltage for solenoid: 24 VDC.
Without indicator 2NC+ 1NC (Slow-action) D4N-2F2H INSTRUCTION sheet.
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast body incorporating a switch box witth,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13 D4N-2F2H Manual.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key ffor a swinging door are available D4N-2F2H Manual.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions.
Related products
OMRON
Safety Limit Switch
D4N-9126
OMRON Safety Limit Switch D4N-9126
Actuator: Roller lever resin lever, earing
OMRON
Safety Limit Switch
D4N-6E31
OMRON Safety Limit Switch D4N-6E31
Actuator: Plunger. Conduit size: 2-conduit
OMRON
Pull-reset Safety Limit Switch
D4N-8A2HR
OMRON Pull-reset Safety Limit Switch D4N-8A2HR
Actuator: Adjustale roller lever, form lock
OMRON
Pull-reset Safety Limit Switch
D4N-2C72R
OMRON Pull-reset Safety Limit Switch D4N-2C72R
Actuator: One-way roller arm lever vertical