Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Sealed roller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection D4N-2B87 INSTRUCTION sheet.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
D4N-2B87
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4N-2B87 INSTRUCTION sheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Head material: Plastic*1.
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC D4N-2B87 INSTRUCTION sheet.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC+1NC/1NO.
Conduit opening: M20.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Roller lever *1, Low-torque.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standdard operating temperature range:
-40°C to +100°C (standard type) D4N-2B87 Manual.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4N-2B87 Manual.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)