Brand: OMRON
Product model: D4N-2280
Name: safety limit switch
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Sealed pin plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models D4N-2280 INSTRUCTION sheet. )
Sealing characteristics that meet IEC IP67 degree of protection D4N-2280
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers D4N-2280 INSTRUCTION sheet.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: SJT(O) cable *3.
Actuator: Sealed pin plunger.
Cable length : 5 m D4N-2280 INSTRUCTION sheet.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Roller lever *1, Standard.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standdard operating temperature range:
-40°C to +100°C (standard type) D4N-2280 Manual.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4N-2280 Manual.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)
Related products
OMRON
Pull-reset Safety Limit Switch
D4N-1C31R
OMRON Pull-reset Safety Limit Switch D4N-1C31R
Actuator: Plunger. Conduit size: 1-conduit
OMRON
Pull-reset Safety Limit Switch
D4N-4C20R
OMRON Pull-reset Safety Limit Switch D4N-4C20R
Actuator: Roller lever resin lever, resin ro
OMRON
Safety Limit Switch
D4N-4122
OMRON Safety Limit Switch D4N-4122
Actuator: Roller lever metal lever, resin ro
OMRON
Pull-reset Safety Limit Switch
D4N-4C2HR
OMRON Pull-reset Safety Limit Switch D4N-4C2HR
Actuator: Adjustale roller lever, form lock