Type: Welding / wire type, with right column.
Driving rod: swing lever type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1a.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment D4JL-2NFA-C7-13 INSTRUCTION sheet.
No swing bars are also used for easy long stroke specifications (OT reference value: 1
D4JL-2NFA-C7-134mm).
Without harmful substances to the environment, the lead type has also been lead-free. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Roller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed D4JL-2NFA-C7-13 INSTRUCTION sheet.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4JL-2NFA-C7-13 INSTRUCTION sheet.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Actuator: Adjustable rod lever.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever.
Eqquipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion D4JL-2NFA-C7-13 Manual.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4JL-2NFA-C7-13 Manual.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.