Type: Welding / wire type, with left column.
Drive rod: needle shaped button type.
Terminal specifications: with wire, under the lead.
Contact specifications: 1a.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation product, which is beneficial to the miniaturization of the equipment D4F-202-5D INSTRUCTION sheet.
No swing bars are also used for easy long stroke specifications (OT reference value: 1
D4F-202-5D4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Classification: Standard models.
Auxiliary outputs: Semiconductor outputs *1.
Cable length: 2 m.
Electronic Detection Mechanism for.
Better Stability in Non-contact Door D4F-202-5D INSTRUCTION sheet.
Switch Operation. Actuator: Arm lever.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
Compact, Plastic-body Safety-door.
Hinge Switch Designed for Saving.
Space in Machines and Other.
Equipment.
Lineup includes three contact models with 2NC/1NO and.
3NC contact forms in addition to the previous contact forms.
1NC/1NO, and 2NC. Models with MBB contacts are also available D4F-202-5D INSTRUCTION sheet.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads. Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Adjustable roller lever.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Slow-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the leverr D4F-202-5D Manual.
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NNEMA 3, 4, 4X, 6P, and 13) D4F-202-5D Manual.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.