Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
2 RS-422A/485 ports; Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave CS1W-CLK52-V1 I/O Wiring Diagram
CS1W-CLK52-V1
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.40A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CS1W-CLK52-V1 I/O Wiring Diagram. Name: Three-tier Screw Terminal Block.
Specifications: Inputs/Outputs;
8 inputs/8 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection CS1W-CLK52-V1 I/O Wiring Diagram.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: PID Control Module.
Model: C200H-PID03.
Output: Current output.1 axis, Pulse train output. directly connects to servomotor driver.Model: C500-CN231.
Cable length: 20 m.
Programming Console Connecting Cable.
For extension and connection of FIT of FIT.
Name: Clamp Terminal Blocks.
Specifications: Inputs/Outputs;
8 inputs/8 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced CS1W-CLK52-V1 Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1W-CLK52-V1 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.