The initial configuration of the G language unit in the industry due to the use of G language,
Complex processing procedures do not need to be able to make the ladder diagram.
The realization of the first 1 axis simultaneous control of 4 axis simultaneous control in the industry is due to the multi task function,
Can be executed at the same time or the 2 axis simultaneous control of 4 axes, and then can achieve the 4 axis independent control, etc CS1D-CPU65H PROGRAMMING MANUAL
CS1D-CPU65H
Up to 8 units can be installed CVM1 8 units can be installed 1 units, can control up to 32 axes.
Applicable to ABS encoder by standard,
Applicable to the ABS type (absolute output) encoder, so after the emergency stop, no need to search for the origin, etc CS1D-CPU65H PROGRAMMING MANUAL. .
S curve also according to the standard configuration plus deceleration curve, in addition to the trapezoidal outside,
Also configured to suppress the mechanical vibration of the S shape curve.
Program login maximum of up to 100
G language can be programmed with the MC support software GFor 5-slot Backplane.C500-NC Special I/O Unit Position Control For pulse motors 1 axis C500-NC113.Specifications: Two RS-422A/485 ports CS1D-CPU65H PROGRAMMING MANUAL. Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems CS1D-CPU65H Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1D-CPU65H Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.