Name: Compact Connectors.
Specifications: Inputs/Outputs; 1 input/1 output; NPN.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery.
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices CRT1-VOD16ML UL Standards and CSA Standards
CRT1-VOD16ML
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price.
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. Required for Analog Input and Output Units: For one Analog Unit.Applicable CPU Units: CQM1H-CPU51/61.
Mounting locations and number of Boards: 1 Board can be mounted in either slot 1 or slot 2 CRT1-VOD16ML UL Standards and CSA Standards.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 60 g max.Protector for Expansion I/O Rack IOIF connector CV500-COV02Name: I/O Control Unit.
Specifications: Applicable systems,
Duplex CPU, Dual I/O Expansion System only;
Duplexing, Supported;
Online Replacement, Supported;
Mounting Backplane, Expansion Backplane;
Connecting Cable, CS1W-CN@@3,
CS-series Connecting Cable CRT1-VOD16ML UL Standards and CSA Standards.
Current consumption: 5V system, 0.20A;
26V system, --.
Standards: UC1, CE.
Redundant CPU Units , Power Supply Units ,
Communications Units ,
and Expansion I/O Cables. Name: e-CON Connectors.
Specifications: Inputs/Outputs;
8 inputs /8 outputs; PNP;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost cann be reduced CRT1-VOD16ML Manual.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CRT1-VOD16ML Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.