OMRON
Home >> Download >> OMRON >> Manual Download >> OMRON CRT1-VDA02SD Manual CRT1-VDA02SD Instruction manual

OMRON CRT1-VDA02SD Manual CRT1-VDA02SD Instruction manual

Brand: OMRON
Product model: CRT1-VDA02SD
Name: analog i/o slave
Sort: Instruction manual
File language: English
File size: 0.68MB
Product name: N@@-type CPU Units with 40 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 24; Outputs, 16;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.21A; 24 V,0.09A.
Standards: UC1, N, L, CE CRT1-VDA02SD Instruction manual.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient CRT1-VDA02SD
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP213-E CRT1-VDA02SD Instruction manual.
4-MB memory; w/o floating-point processor.C200H-CPU31-E CPU
High-Performance CIM Version
The C200H-CPU31-E controller offers a high-performance CPU especially designed for computer integrated manufacturing environments.
The C200H-CPU31-E has all the capabilities of C200H C200H CPU21/CPU23,
with clock/calendar as a standard feature.This CPU is used in either SYSMAC NET and/or SYSMAC LINK communicationNumber of outputs: 8 pts CRT1-VDA02SD Instruction manual.
Input Voltage: 250 VAC, 24 VAC.
Max Switching Current: 2 Amps.
Common Type: Independent.Unit type: CJ1 Basic I/O Units.
Product name: Interrupt Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24 VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumpttion: 5V, 0 CRT1-VDA02SD Manual. 08A; 24V, --.
Standards: UC1, N, L, CE.
High-speed Starting of I/O InterruptTasks.
Use Up to Two Units for a Total of Up,
to 32 Interrupt Inputs.
Receive inputs to start I/O interrupt tasks.
When the Interruptt Input Unit receives an input,
the CPU Unit will interrupt execution of the,
cyclic tasks in the normal CRT1-VDA02SD Manual.
program and execute an I/O interrupt task.
Related products
OMRON
CompoNet Gateway Unit for CC-Link
CRT1-VID08S-1
OMRON CompoNet Gateway Unit for CC-Link CRT1-VID08S-1
Name: e-CON Connectors. Specifications: Inpu
OMRON
Analog I/O Slave Units
CRT1-VDA02MLD
OMRON Analog I/O Slave Units CRT1-VDA02MLD
Name: Analog I/O Slave Units, Numerical ind
OMRON
CompoNet Gateway Unit for CC-Link
CRT1-VMD32ML
OMRON CompoNet Gateway Unit for CC-Link CRT1-VMD32ML
Name: MIL Connectors. Specifications: Inputs
OMRON
CompoNet Gateway Unit for CC-Link
CRT1-VOD08S-1
OMRON CompoNet Gateway Unit for CC-Link CRT1-VOD08S-1
Name: e-CON Connectors. Specifications: Outp