Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 8 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 4 to 20mA;
1/4,000 (Settable to 1/8,000) *2.
Conversion period: 1 ms/point,
(Settable to 250 μs/point)*2.
Accuracy at ambient temperature of 25°C:
±0 CJ1M-CPU13 PROGRAMMING MANUAL. 3% of F.S.
External connection: Removable terminal block
CJ1M-CPU13
External power supply: 24 VDC +10% -15%, 170mA max.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.14A; 24V, 0.17*3.
Standards: UC1, N, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data CJ1M-CPU13 PROGRAMMING MANUAL.
Analog Output Units for converting binary ,
data into analog output signals. Number of inputs: 8 pts.
Input Voltage: 100 to 120V DC.
Input Current: 5 mA.Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: Set separately for each input.
Signal range; Resolution: 1 to 5 V (1/10,000),
0 to 10 V (1/20,000), -5 to 5 V (1/20,000),
-10 to 10 V (1/40,000), and 4 to 20 mA (1/10,000) CJ1M-CPU13 PROGRAMMING MANUAL.
Conversion period: 20 μs/1 point, 25 μs/2 points,
30 μs/3 points, 35 μs/4 points,
The Direct conversion is provided.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.4% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.52A; 24V, --.
Standards: UC1, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals.
C500-OC I/O Unit Transistor Output 32 pts C500-OC224(3G2A5-OC224).
AC250/DC24V 2A.C500-OD I/O Unit Transistor Output 32 pts C500-OD415CN(3G2A5-OD415CN).
DC12~48V 0.3A.Unit classification: CJ1 Special I/O Units.
name: Position control unit.
Specifications; Control method/Control,
output interface:Open-loop control by pulse,
train output/Open-collector output;
Number of control axes : 1 axis.
No. of unit numbers allocated: 1.
Currrent consumption: 5V, 0 CJ1M-CPU13 Manual. 25A; 24V, --.
Standards: UC1, CE.
High-speed, High-precision positioning,
with 1, 2, or 4 axes.
Versatile functions and superb performance,
enable the construction of compact,
high-performance machiines CJ1M-CPU13 Manual.
With its ultra-compact size of 31 × 90mm (W×H),
this highly space-efficient Position Control Unit,
(PCU) enables up to 4 axes of motor control.