Supply voltage: 100 to 120 or 200 to 240 VAC (automatic voltage setting), 50/60 Hz
Operating voltage range: 85 to 132 or 170 to 264 VAC
Power consumption: 200 VA max.
Output capacity: 12 A, 5 VDC Power supply: AC power supply.
Output method: Relay output.
Inputs points: 6 points CS1W-PTS02.
Outputs points: 4 points.
Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Resistance Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input CS1W-PTS02.
I/O type: Pt100, JPt100.
Conversion speed (resolution):
100 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.15A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices CS1W-PTS02.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON CS1W-PTS02.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them OMRON CS1W-PTS02.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems.
High-resolution Models and 8-point Input Models are,
also available OMRON CS1W-PTS02.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. C500-OD I/O Unit Transistor Output 16 pts C500-OD217(3G2A5-OD217).
DC12-24V 1A.UM: 7.2K words.
DM: 6K words.
EM: --.
Instruction processing time (basic instructions): 0.3 micro s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.Max. no. of connecting High-density I/O Units(i.ee CS1W-PTS02., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.I/O bits: 5, 120 (Expan-sion Racks: 7).
Program capacity: 30K steps.
Data memory capacity: 64K words (DM: 32K words, EM: 32K words ×1 banks).