I/O points: 128 pts.
Program capacity(words): 3.2 K.
DM capacity (words): 1 K.
RS-232C port: NO.Model: C500-CN131.
Cable length: 10 m.
Programming Console Connecting Cable.
For extension and connection of FIT of FIT.
Product name: N@@S1- type CPU Units with 30 I/O Points CP1E-N30S1DR-A.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 18; OOutputs, 12;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0
CP1E-N30S1DR-A.30A.
Current consumption: 5 V, 0.21A; 24 V,0.07A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CP1E-N30S1DR-A. 4 platinum resistance thermometer inputsModel: C200HS-INT01.
Rated Input Voltage: 12 to 24 VDC +10%/–15%.
Input Impedance: 2 K.
Input Current: 10 mA typical (24 VDC) OMRON CP1E-N30S1DR-A.
ON Voltage: 10.2 VDC min.
OFF Voltage: 3.0 VDC max.
ON Response Time: 0.2 ms max.
OFF Response Time: 0.5 ms max.
No. of Circuits: UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0 OMRON CP1E-N30S1DR-A.15 µ.s min.
No. of I/O points: 880 points.
Max. no.of con-necting Expansion I/O Racks: 2 Racks.
Max. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max. no. of con-necting Special I/O Units: 10.
RS-232C: NO.Name: Temperature Sensor Module OMRON CP1E-N30S1DR-A.
Model: C200H-TS101.
Temperature sensor: RTD (JPt 100 Ω.).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).Power supply: AC power supply.
Output method: Transistor output sink type.
Inputs points: 12 points.
Outputs points: 8 points.Unit type: CJ1 CPU Bus Units.
Product Name: Serial Communications,
Units High-speed type.
Specifications:Communications Interface,
2 RS-232C ports; Communications functions,
The following functions can be selected,
for each port with an CJ system:
Protocol macro, Host Link, NT Links (1:N mode),
Serial Gateway, No-protocol, Modbus-RTU Slave,
The following functions can be selected,
for each port with an NJ system: Protocol macro,
Serial Gateway, No-protocol, Modbus-RTU Slave.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.28A; 24V,--.
Standards: UC1, N, L, CE.
The Serial Communications Units That Enable,
High-speed Connections with External Devices.
Each Serial Communications Unit provides two,
serial communications ports: RS-232C and,
RS-422A/485, and the serial communications,
mode can be set separately for each port from,
Protocol Macro, Host Link, NT Link,
Serial Gateway, and No-protocol CP1E-N30S1DR-A.